Dg5s4 vickers pdf merge

Seal kit note valves are manufactured with f3 seals used internally. Vickers 871076 dg4v series solenoid operated 4 way hydraulic valve, 5075 psi maximum pressure, open spring offset spool type, 110120 vac, 16 gpm flow rate. Buy vickers eaton hydraulic directional control valves dg5s4042cmub560 direct from motion industries. Vickers dg4v3s2amuh560 directional control valve from ims supply. Dg5s406ch51, directional valves with oil immersed solenoids, legacy design english, parts, service and repair. Dg5s4040610 dg3s8dg5s df5s41624 mod dg17s40106 dg17v3 c552c572 dg5s4h 06 dg5sh8 dil dg17s8 dg18s4 racine piston pumps c11 c4 c5 all manufacturers names, numbers, and descriptions are used for reference purposes only.

The information in this guide is the most recent information available, either in printed cata. Eaton vickers atexrated solenoid operated directional valves dg4v3sx6 design vvldimc010e november 2008 7 performance data typical with mineral oil at 36 cst 168. Austinwestern clark euclid michigan michiganclark volvo. Up to 120 litres per minute dependant on spool mounting surface. Sequence 2 valve type dg5s4 solenoid operated directional control valve with 210 bar max dg5s4 2.

This in turn,would control the direction of movement cylinder,or the rotation of an oil motor. This, in turn, would control the direction of movement of a hydraulic cylinder, or the rotation of a fluid motor. Iso 4401 size 05 nfpa d02 din 24340 ng10 a range of fourport solenoid operated directional control valves with fourland spool design to. Dg5s410dw353, wet armature, pressure centered, solenoid controlled. Solenoid controled pilot operated directional valve. Pilot operated directional control valves directional controls. D 5s4 l directional valve, flange connection, subplate or manifold mounted, solenoid controlled, pilot operated, sliding spool, 4 way solenoid l solenoid indicator lights omitted none series 06 60 10 10 16 160 type of main stage spool spring a spring offset b spring centered one solenoid c spring centered d pressure centered. For products in this catalog the recommended levels are. Hydraulex is a family of attica hydraulic exchange, flint hydrostatics, hydraulic repair and design and metaris hydraulics.

A relief valve controls flow in one direction, and a check valve allows for free reverse flow. Dg5s410 90 uses a dg4v3s60 standard d03 pilot valve 100 bar 1450 psi. Hydraulic direction control dg4v3 vickers related article selection of pressure hydraulic direction control valve. The book also includes information on the vickers concept of proactive maintenance. It is not to be implied that any item is the product of these manufacturers. A complete parts breakdown is contained in this drawing. Eatonvickers cartridge valves are similar to poppet check.

The information contained herein pertains to the latest design series as listed in table 1. Directional controls soft shift directional control valve. V10 and v20 models can be provided with integral valving to limit. Solenoid controlled pilot operated rated pressure 210 bar 3000 psi 12 3456789101112 interface spool type see table spoolspring arrangement a spring offset, to cyl. Dg5s4100 dg5s4101 dg5s4102 dg5s4103 dg5s4104 dg5s4106 dg5s4108 dg5s4109 dg5s41011 dg5s41031 dg5s41033 364037 331404 364038 277479 281193 364039 364041 277563 331404 277479 364042 400975 note sae straight thread plugs used on exterior of valve. Related publications service parts information and installation dimensions are not contained in this manual. Counterbalance, sequence and pressure reducing valves dgmr4 dgmx34 general description these singlestage valves operate by the application of pressure on the end of the valve spool, acting against a spring which is loaded by means of the adjustment mechanism. This in turn would control the movement of a work cylinder or the rotation of a fluid motor. Slipin cartridge valves to iso 7368 din 24342 eriks. Vickers service data directional controls solenoid.

Dg4v360,dg4v3 vickers valve quick delivery,bulk purchasing. Vickers directional controls directional control valves wet armature solenoid operated dg4s 01, 60 design. Related publications contd model description 1011 design dg5sh8abcn dg5s8abcn. Xdg5s406c51, directional valves for use in hazardous locations english, parts, service and repair. Dg5s404 models are twostage directional valves having an integrally mounted dg4v3 s60 pilot valve. Powrflowtm vsd05 directional control valve competitive.

Vickers dg4v 5 2a m u a6 20 solenoid operated directional. Your proven service leader with reliable delivery since 1972. Vickers eaton dg4v 5 2a mu a6 20 motion industries. With our combined expertise, capabilities, and inventories we have the largest offering in the industry of remanufactured, aftermarket, and oem hydraulic components and parts. Dg5s4 04k dg5s4 04 r dg5s4 04s spring 426859 418675 432350 b plug p port see table 298129 screw 4 reqd torque 37 45 n. Counterbalance valves control negative or overrunning loads by. Spring offset for single stage operation, one spring returns the spool to an offset position. The following recommendations are based on iso cleanliness levels at 2 m, 5 m and 15 m. Vickers hydraulic valves attica hydraulic exchange, inc. Recommended cleanliness levels using petroleum oil under common conditions is based on the highest fluid pressure levels in the system. A removed c spring centered f spring offset, to cyl. Vickers directional controls pilot operated directional. Vickers dg4s401 60 series wet armature flows to 25 gpm, 4way, 3position, spring centered spool spring code 2c. These valves are generally used to control the direction of flow in a hydraulic circuit.

Eaton vickers industrial valves vvlovmr002e september 2006. Consult vickers with application details if any of the following are required. If we dont have the exact vickers pump on the shelf it doesnt matter, as we keep all the shafts, end covers and compensators so we can usually build the vickers pumps to your specification. Directional valves with oil immersed solenoids these parts service parts information the same change applies to this end for models with two solenoids 251505 232960 195053 240996 323163 195054.

Each valve contains a mainstage spool which is positioned by one of four special arrangements, which are. Electromagnetic compatibility emc it is necessary to. A pilot pressure connection controls the relief valve setting in its counterbalance function. A shift to center n no spring detented manual override option seals for. What you want to do is called imposition you want to impose the two pages on one sheet. Service data directional controls solenoid controled pilot. Trouble with the curve if you are areader who likes to yltra a perfect life danielle steel pdf to any kind of device,whether its.

Directional control valve advanced fluid power, inc. Related publications service parts and installation dimensions are not contained in this manual. Vickers, dg4v3, dg4s401, dg5s404, dg5s406, dg5s8, dg5s410. Vickers dg3v10 and dg5v10 series single stage and two stage pilot operated and hydraulic operated directional valves. New free shipping on all orders in the contiguous usa. Reliable and continuous performance in the worlds most.

Dg5s4 dg5s4 solenoid operated directional control valve with 210 bar max. Directional controls directional controls associated group. Cartridges combine functions of direction, flow andor pressure. Single fixed displacement vickers offers an extensive line of fixed displacement single pumps with displacements from 3,3 to 215 cm 3r. Vickers dg3s4, dg4s4, dg4v, dg18v, dg19s and df5s series single stage and two stage directional valves. Pressure hydraulic direction control dg4v360 to control the hydraulic system pressure, therefore the selection should be based on the working state of the hydraulic system, the pressure on the requirements and dg4v360 hydraulic direction control valve in the system to the. Basically, these solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. Vickers systemstak counterbalance valves are available with single and double control. Refer to specific vickers parts drawing for service parts information. Recommendation of filtration and the selection of products to control fluid condition are included in 561. Dg5s55 solenoid controlled and pilot operated directional.

Vickers piston pumps pvh series pumps pvh57, pvh74, pvh98, pvh1. Acrobat does not come with imposition features built into the application, you would need to use a 3rd. Vickers general product support guide to industrial hydraulics. Stroke adjustment parts either end or both for satisfactory service life of these components in industrial applications, use full flow filtration to provide fluid which meets iso cleanliness code. Sequence 2 valve type dg5s4 solenoid operated directional control valve with 210 bar max. Vickers 871076 dg4v series solenoid operated 4 way. Argo hytos cetop 3 nk6 vickers cetop3 nk6 vickers osanumero nk6 argo hytos cetop 5 nk10 vickers cetop 5 nk10 vickers osanumero nk10 rpe3062r1101200e1 dg4v30amug760 869858 rpe4102r1101200e1 dg4v50amug620 616957. Competitive crossover guide this crossover guide compares performance and specifications of solenoid operated nfpa d05 mounting directional control valves. Vickers directional controls wet armature solenoid.

997 791 1470 764 762 1369 547 1409 655 300 838 1511 628 931 1144 1099 416 286 1025 275 791 695 720 175 501 529 617 889 1003 89 671 774 562 1236 487 1383 919 368 1488 672 1041 950 832 1374 583 203